Get complete information related to latest Crane Wire Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Crane Wire Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Crane Wire Tenders.
Tender For supply of upgradation of mcc panel for centralized ac system - mcc panel , main incomer , outgoing 37.5 kw 50 hp start or delta starter feeder for 3 nos 50 hp chiller package , outgoing 2.2 kw dol starter feeder for cooling tower motor , outgoing 5.5 kw dol feeder for condenser pump , outgoing 3.7 kw dol feeder for chiller pump , power cable for chiller package , power cable for 4 nos chilled water pump dol starter , power cable for 4 nos condenser water pump dol starter , power cable for 3 nos cooling tower motor dol starter , control power for 3 nos cooling tower push button , internal wiring and ferrules , earthing , accessories for complete project , dismantling of existing unit and installation, testing and commissioning of mcc panel
Tender For supply of electrical panel with accessories - c83640001432 supply of electrical panel along with busbar - incomer - outgoing - refer annexure 5a - scope of supply , 100000000001 supply of ip55 or above outdoor distribution box having 200a mccb 25ka incomer - refer annexure 5a - scope of supply , 100000000002 supply of ip55 or above outdoor distribution box having 150a mccb 25ka incomer - refer annexure 5a - scope of supply , 100000000003 supplying of lt power cable with aluminium conductor xlpe insulated pvc inner sheathed galvanised steel-3point5 core of size 70sqmm-refer annexure 5a-scope of supply , 100000000004 supplying of lt power cable with aluminium conductor xlpeinsulated pvc inner sheathed galvanised steel-having 3point5 core of size 300 sqmm-refer annexure 5a-scope of supply , 100000000005 supplying of end termination kit with brass compression gland and aluminium lugs for 3point5c x 70sqmm-refer annexure 5a-scope of supply , 100000000006 supply of end terminations kit of 3point5 core 300 sqmm size of cables - refer annexure 5a - scope of supply , 100000000007 supply of material for earthing with copper earth plate 600 mm x 600 mm x 3 mm thick refer annexure 5a - scope of supply , 100000000008 supply of 25 mm x 5 mm copper strip at 0point50 metre below ground -refer annexure 5a - scope of supply , 100000000009 supply of material for earthing with gi earth plate 600 mm x 600 mm x 6 mm thick -refer annexure 5a - scope of supply , 100000000010 supply of 25 mm x 5 mm gi strip at 0point50 metre below ground as strip earth electrode -refer annexure 5a - scope of supply , 100000000011 supplying of 90 mm dia od 90 mm and id 76 mm nominal size hdpe pipe isi marked-refer annexure 5a - scope of supply , 100000000012 supplying of materials for in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level -refer annexure 5a - scope of supply , 100000000013 shifting loading unloading placing installation testing and commissioning of above mentioned panel this includes foundation civil work-refer annexure 5b-scope of erection , 100000000014 shifting loading unloading placing installation testing and commissioning of above mentionedrefer annexure 5b-scope of erection , 100000000015 making end termination with brass compression gland and aluminium lugs for 3point5c x 70sqmm size of pvc insulated -refer annexure 5b - scope of erection , 100000000016 making end terminations of 3point5core 300 sqmm size of cables -refer annexure 5b - scope of erection , 100000000017 installation testing and commissioning of earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories -refer annexure 5b - scope of erection , 100000000018 installationtesting and commissioning of 25 mm x 5 mm copper strip -refer annexure 5b - scope of erection , 100000000019 installation testing and commissioning of earthing with gi earth plate 600 mm x 600 mm x 6 mm thick including accessories-refer annexure 5b - scope of erection , 100000000020 installation testing and commissioning of 25 mm x 5 mm gi strip-refer annexure 5b - scope of erection , 100000000021 laying of one number pvc insulated and pvc sheathed xlpe power cable above 35sqmm and upto 95 sqmm-refer annexure 5b - scope of erection , 100000000022 laying of one number pvc insulated and pvc sheathed xlpe power cable above 185 sqmm and upto 400 sqmm-refer annexure 5b - scope of erection , 100000000023 laying of one number pvc insulated and pvc sheathed xlpe power cable above 185 sqmm and upto 400 sqmm -refer annexure 5b - scope of erection , 100000000024 laying and fixing of one number xlpe or pvc insulated and pvc sheathed or xlpe power cable -refer annexure 5b - scope of erection , 100000000025 mouling through the existing roads in any kind of soil-laying of hdpe pipe 90mm pipes for cables etc-refer annexure 5b-scope of erection , 100000000026 excavation of the cable trenches in hard rock not exceeding 1point5 metres in width a
Tender For corrigendum : lifts (passenger & goods), technical confirmation list for lifts (passenger & goods, job specification (static & machinery equipment), for lifts (passenger & goods), data sheet for lift (000-lz-l01 a/b), data sheet for lift 1000-lz-l02), data sheet for lift (000-lz-l03), location & landing platform for lift in pfs shed of sru, instrumentation cum mechanical building, standard specification for electric fraction lift, vendor data requirements, job specification for lifts, vendor data requirements for lifts, maridatory spare list (electrical)-lift package, approved vendar list (electical)-lif package, data sheet mv ind motor for lift, data sheet vfd for lifts, data sheet lift package pdb, data sheet mv swbo compilift package), hardware datasheet for outgoing motor feeder (rating55kw), hardware datasheet for outgoing mccb leeder, hardware datasheet for outgoing mccb contactor feeder, specification for mv switchboards fixed type for package equipment, specification for industrial type control stations, specification for medium and high voltage cables & accessories, specification for communicaton and fire alarm cables., specification for energy efficient medium voltage induction motor, specification for electrical equipment installation, specification for cable installation, specification for lighting installation, specifications for earthing installation, specification for electrics of package equipment, itp for mv fored hype switch board for package equipment, itp for industrial type control stations, itp for mv vanable frequency drive system, itp for my & hv cables & eccessories, itp for communication & fire alarm.cables, inspection and test plan for energy efficient medium voltage motors, equiment earthing schedule, instructions to vendor for sile performance guarante, requirements for peckage units, standard specification for health, safety & environmental management at construction sites, specification for quality management system requirements from bidders, specification for documentation requirement from contractors, specification for documentation requirement from suppliers
Tender For supply and installation of necessary equipment for updating the fire and safety system installed in regional office, chandigarh - diesel engine driven main fire pump supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (diesel driven pump) horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to is 1520. suitable hp, 1500 rpm water cooled with radiator, diesel engine conforming to relevant is standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. m.s fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. suitable cement concrete foundation duly plastered and with anti vibration pads.(for 1620 lpm at 56 m head) note- the head of the pump is selected in a manner so as to give a minimum 3.5 kgf/cm2 pressure at the highest farthest point., control panelfabrication, supply, installation testing & commissioning of electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick crca sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, inter connection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per cpwd specification with following in coming and outgoings, suitable for operation on 415v, 3 phase, 50hz ac supply with enclosure protection class ip 42 as required :incoming250a, 50ka 4 pole mccb, ics=100% icu rating ,digital voltmeter 0-500v with selector switch digital ammeter (0-250 a) with selector switch & cts etc. led type ryb phase indicating lamps, on, off, trip indicating lamps, set of copper bus bar 300a.outgoing( note : all outgoing feeders for pumps should have digital ammeter with selector switches, and led type on, off, trip indicating lamps)main fire pump125 a, 50ka tpn mccb, ics=100% icu, with fully automatic star/delta starter suitable for 60 hp pump with overload protection, current sensing type single phase preventer complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/off operation.jockey pump63 a, 50ka tpn mccb, ics=100% icu, with suitable hp fully automatic star/delta starter with overload protection, current sensing type single phase preventer complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/off operation.diesel engine controlcontrol for diesel engine comprising -automatic/manual selector switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode indicating lamp for high/ low lub. oil pressure, high water temp and engine on indication, battery charger suitable for 12v/24 v dc with boost and trickle selector switch, 0-30 v dc volt meter, and 0- 20 a dc ammeter. all standard relays and accessories for automatic operation of diesel enginesystem controllerdesigning, supply, installation, testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, pressurization pump, terrace pump in sequence as per specification consisting of relays, timers. sensors, annunciat
Tender For custom bid for services - provision of standby pump and associatedworks at main water supply pump house at af station samana-1. supply, installation and commissioning of submersible pump set 30 hp having discharge of 1650-500 lpm and head 47-78m electric driven 415 v, tp suitable open well (outlet size for 80*65mm dia) supply and install complete inclusive of 20 meter long 25 sqmm 3 core flat submersible cable, chain for supporting and taking out set mounting arrangement. nos 01, 2. supply, install, testing and commissioning and testing factory made and tested (including cpri type test certified) lt feeder pillar box (kiosk) outdoor type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 hz ac supply system, all as specified and directed, having bus bar chamber with insulated copper bus bars 350 amps rating installed on porcelain insulators. the panel shall be dust and vermin proof, made of 3.15mm crca ms sheet 75mm x 30mm thick ms channel frame, duly powder coated finish. front opening type with aprons for cable entry with double door shitter and locking arrangement, danger plate and earthing terminal. the scope of work includes pcc foundation and provision of the following :- incoming (a) mccb 4 pole 200 amps, 36 ka, 415 v - 01 nos (b) bus bar aluminum strip 400 amp, 4 pole, for in comp supply - 01 nos (c) digital panel meter including cts - 01 no outgoing (a) mcb tpn 40 amp 6 ka, 415 v 50 hz - 02 nos (b) mccb tpn 80 amp 16 ka, 415 v 50 hz - 01 no (c) star delta starter panel with suitable thermal overload protection, sppr, overvoltage, overcurrent and surge protection for 30 hp - 02 nos (d) low water level motor cutoff sensor with wire 20 mtr - 02 nos (make gic or slect control pvt ltd.). each 01, 3. supply and fix pressure guage upto pn-40 rating all as specified and as directed by engineer-in-charge. each 10, 4. supply and fixing hdpe pipe 90 mm dia pn 16 pressure rating with connected items all as specified and as directed by engineer-in-charge. rm 15, 5. supply and fix, gi sluice valve confirming to is 13095, 100 mm (4 ) dia with flanges end v all as specified and directed by engineer-in-charge., 6. material and labour in replacement for construction of valve chamber of size 1200 x 900 x 900 mm deep dimensions (over all internal dimension) for sluice valve etc. with pcc foundation, pcc block masonry walls, plastering, pcc coping, white washing, mild steel chamber cover, painting to chamber cover including excavation and earth work in any type of soil complete all as specified below :- valve chamber shall be provided with the following specifications :- (i) cement concrete for foundation (1:4:8) type d2 using 40mm graded stone aggregate 150mm thick extended upto 150 mm beyond the outer face of block masonry. (ii) walls of valve chamber 200 mm thick with precast cement concrete (1:5:8) (using 20 mm graded stone aggregate) solid building blocks, setting in cm 1:6 complete. (iii) internal and exposed surfaces of valve chamber both concrete and block masonry surface shall be plastered with cm 1:4 15 mm thick finished even and smooth. (iv) 50 mm thick coping in pcc 1:3:6 type c1 over block masonry wall. (v) entire plastered surfaces shall be treated with 3 coats of white wash. (vi) chamber cover shall be of 6 mm thick fiber reinforced polymer (frp) sheet with 30 x 30 x 5 mm size angle iron frame with hold fast and locking arrangement. steel furface shall be painted with two coats of synthetic paint of first quality over one coat of red oxide primer. each 01, 7. supply and fix 100 mm non return valve conforming to is 13095, 100 mm (4 ) dia with flanges end all as specified and directed. each 02, 8. supply and fix galvanized iron heavy grade pn 16 rating y section with flanged end 2 openings 100 mm dia and one 180 mm dia with suitable flanges and bots flanges end v all as specified and directed. kg 25-msme exemption - yes | startup exemption - yes
Tender For supply of 4.5kw brushless alternator including rectifier cum regulator along with belt tensioning device for 110v dc train lighting system as per rdso specn no.rdso/pe/spec/tl/0054-2003 rev '0' with amendment no.1&2. each set consists of (a)one alternator with 2nos of safety chains(b)one alternator pulley with securing nut & locking arrangement(c)one rectifier cum regulator(d)crimping socket for alternator and regulator for outgoing/incoming cable(e)one tensioning gear assembly(f)one langer pin to suspend the alternator(g)one axle pulley,2nos rubber pads and fasteners etc(h)one instruction manual.
Tender For corrigendum : mrss electrical aux power supply modification work - supply of 1.1kv grade,1corex240sqmm cable, alconductor, xlpe, strip armoured, pvc inner sheath, is7098 part-2, make:- havells, kei,kec,gloster, polycab,universal , laying and termination of 1cx240sqmm , al , armoredcable, lt cable, in over head manner as per instructionof engineer in charge , supply and providing al lugs 240sqmm for xlpe cable , supply and providing glands, double compressor brassglands, for 240sqmmx1c, xlpe cable , supply of pdb, 400amps incoming as per ts annexure , installation of pdb with termination of incoming and outgoing existing cables , dismantling and relocation of old pdb from shop floorwith dismantling of incoming and outgoing cables andother supports as per instruction of engineer incharge(avg size- 1.5x0.45x1.5 mtrs) and fixing at newlocating with incoming and outgoing cable terminationsand support structures(all required items shall beprovided by midhani) , supply installation testing commissioning and wiring of5kva online ups with necessary battery bank for fullload backup up to 2hrs. input 415v 3 ph or 1 ph 230v,+/-10% variation frequency 50hz, with neutral, output230vac single phase, frequency variation +/- 5%,harmonics <5%, voltage regulations < 2%,ip20,efficiency= 90% or higher, inbuild over load protection,front touch screen or buttons, with sealed maintenancefree battery/vrla bank with stand of suitable rating.sizing calculation of battery to be submitted, makemicrotek, hi- rel,emerson,vertive,luminous,numeric,eaton,apc.battery make- amararaja,exid , supply installation testing and commissioning of dualfloat cum boost battery charger with battery bank40amps as per technical specification. , supply and installation of ups distributionboard,incoming- b-curve-1x25amps, mcb, 10ka, 2 pole,230vac, out going- b- curve(all) 2x16amps mcb, 10ka 1pole, 6x6amps mcb 10ka, 1 pole make (mcb)- legrand,l&t, havells, schneider, 25ka, 4 pole, without door type /suitable encloser metalbox of size- 400x400x300(d)mm, wall mounting type,front door, operating handle , gland plate of size150x150mm on top and bottom, make (mccb)- legrand,havells, schneider, l&t
Tender For supply of 11 kv 24 panel switch board - design engineering manufacturing shop testing inspection packing delivery to site of 11 kv switchboard , spare incomer breaker with trolley and 3 phase line pt mounted , spare outgoing breaker with trolley of each size and rating , numerical feeder protection and control relay of each type , numerical transformer differential protection and control relay of each type , single phase current transformer for each type and rating , single phase current transformer for differential protection for each type and rating , pt primary fuse of each rating , pt secondary fuse mcb , spring charging motor , surge arresters , tnc control switch , closing coil , tripping coil , ammeter selector switch , voltmeter selector switch , bus support insulator used in bus bar compartment of each type , bus support insulator used in cable compartment of each type , anti pumping relay , dc failure relay , master trip relay , 24 window annunciator , 10 window annunciator , hooter , led indication lamps 110v dc for each colours red yellow biue green clear white amber , led indication lamps 110v ac for each colours red yellow and biue , service test limit switches of each type and rating , limit switches used in vcb of each type and rating , electrical contact grease , installation and commissioning support as per engineering specification cd css 11kv sb es.
Tender For supply, erection, testing & commissioning of lt panel consisting of 400a 50 ka 4 pole microp rocessor based mccb-02 nos. as incoming, 200a/250a 36ka 4 pole microprocessor based mccb-03 nos., 6 3a 36ka 4 pole microprocessor based mccb-02 nos. and 63a 10ka dp 2pp mcb-02 nos., as outgoing, all mc cbs, shall be with rotary switch, with voltmeter, ammeter, led indicator lamp, cu. bus bar, neutral link, ear th bar, spreader link, lock and key feature arrangement cable gland etc. with suitable sheet steel enclosur e conforming to cege/grc?s specification no. ser/elec/gs/description/ltpanel/1/rev-0/mar 2024. min imum size of panel 1800 mm (h) x 2400 mm (l) x 600 mm (d). [ warranty period: 30 months after the d ate of delivery ]